Recurrent Laryngeal Nerve Palsy (RLNP) is the most common complication of thyroid surgery. Patients complain of hoarseness of voice and sometimes variable amount of respiratory distress due to palsy of recurrent laryngeal nerve (RLN), extra laryngeal branches of which are often ligated along with Inferior Thyroid Artery (ITA) during thyroidectomy. So prevalence and variable pattern of extra laryngeal nerve branches (ELNB) of RLN should be known to the thyroid surgeon to avoid post operative complications.


Materials and Methods  


Dissection was carried on the neck of properly embalmed 25 adult cadavers including both sexes in the dissection hall to study extra laryngeal nerve branches (ELNB) of 50 RLN specimens.


Results


Out of 50 RLN, 13 nerves (26%) have ELNBs. Only in 4 cadavers (16%) they are bilateral. In 9 cases RLN branches were surrounding either single trunk of ITA or branches of the artery. In rest of the 4 cases ELNBs were passing entirely either in front or behind the ITA


Conclusion


The gold standard for preservation of the RLN during thyroid surgery is still visual anatomical identification. Proper dissection and anatomical identification of the RLN and all its branches is very important prior to the clamping of the ITA and all its branches.

Article Details

How to Cite
1.
Nandy S, Banerjee A, Das S. A Cadaveric Study of Occurrence of Extralaryngeal Branches of the Recurrent Laryngeal Nerve with Reference to its Importance in Thyroid Surgery. BJOHNS [Internet]. 2020Jul.28 [cited 2024Aug.5];26(3):207-12. Available from: https://bjohns.in/journal3/index.php/bjohns/article/view/210
Section
Main article
Author Biographies

Shantanu Nandy, Medical College, Kolkata

Anatomy

Associate Professor

Anirban Banerjee, IQ City Medical College, Durgapur

Assistant Professor

Department of Anatomy

Saumik Das, Medical College, Kolkata

Otorhinolaryngology (ENT)

Associate Professor

References

Ludlow CL, Bielamowicz SA. Neurogenic disorders of the larynx. Chapter 79. In : Snow B James Jr, Wackym P Ashley,Eds. Ballenger’s Otorhinolaryngology. 17th edition. Shelton, Connecticut. B C Decker Inc / People’s Medical Publishing House. 2009. p 916

Suzuki M, Kirchner JA, Murakami Y. The cricothyroid as a respiratory muscle: Its characteristics in bilateral Recurrent Laryngeal Nerve Paralysis. Ann Otol Rhinol Laryngol. 1970; 79: 976-83

Giovanni SD, Clawdia A, Agala T et al. The recurrent laryngeal nerve related to thyroid surgery. The American J Surgery 1999;177: 485-8

Cummings WC, Fredrickson MJ, editors. Otorhinolaryngology : Head and Neck Surgery. 3rd ed. Vol 3. USA. Mosby. 1998. P. 2445-9

G J Romanes,editor. Cunningham’s Manual of Practical Anatomy. 15th ed (Reprint). Vol 3. Oxford. Oxford University Press. 2006. p. 65-9

Giddings AE. The history of Thyroidectomy. J R Soc Med. 1998; 91 (Supp33) 3-6

Farquharson M, Moran B. Farquharson’s textbook of operative general surgery. 9th edition. Great Britain (London). Hodder Education. 2005. p163-8

Hayward NJ, Grodski S, Yeung M, Johnson WR, Serpell J. Recurrent laryngeal nerve injury in thyroid surgery: a review. ANZ Journal of Surgery [cited 18th September,2012]. DOI: 10.1111/j.1445-2197.2012.06247.x

Harold Ellis: A History of Surgery. 2001, Chapter 13. p 199- 205

Titche LL. Causes of recurrent laryngeal nerve paralysis. Arch Otolaryngol. 1976; 102: 259-61

Karlan MS, Catz B, Dunkelman D et al. A safe technique for thyroidectomy with complete nerve dissection and parathyroid preservation. Head Neck Surgery 1984; 6: 1014-9

Max MH, Scherm M, Bland KI. Early and late complications after thyroid operations. South Med J. 1983; 76(8): 977-80

Riddell VH. Injury to recurrent laryngeal nerves during thyroidectomy - a comparison between the results of identification and non-identification in 1022 nerves exposed to risk. Lancet 1956; 2:638-41

Ozer M, Gokhan I, Mustafa Y, Mahir A, Enis Y. The recurrent laryngeal nerve and the inferior thyroid artery—anatomical variations during surgery. Langenbecks Arch Surg. 2008. 393:681-5

Nemiroff PM, Katz AD. Extralaryngeal divisions of the recurrent laryngeal nerve. Surgical and clinical significance. Am J Surg. 1982. 144:466-9

Katz AD, Nemiroff P. Anastamoses and bifurcations of the recurrent laryngeal nerve—Report of 1177 nerves visualized. Am Surg. 1993. 59:188-91

Katz AD. Extralaryngeal division of the recurrent laryngeal nerve. Report on 400 patients and the 721 nerves measured. Am J Surg. 1986. 152:407-10

Kandil E, Khalek MA, Aslam R, Friedlander P, Slakey D, Bellows CF. Recurrent laryngeal nerve: Significance of the anterior extralaryngeal branch. Surgery 2011; 149(6): 820-4

Jacob SM, Karen JPD, Ryner JCC. The Recurrent Laryngeal Nerve in Relation to the Inferior Thyroid Artery in Adult Filipino Cadavers. Philippine Journal Of Otolaryngology-Head And Neck Surgery 2011; 26(2):13-7

Pradeep PV, Jayashree B, Harshita SS. A closer look at laryngeal nerves during thyroid surgery: a descriptive study of 584 nerves. Anat Res Int. 2012;2012:490390

Stranding S, editor in chief. Gray’s Anatomy. 40th edition. Churchill Livingstone Elsevier. 2008. Chapter 34. Page 577-93

Sinnatamby CS, editor. Last’s Anatomy : Regional and applied. 12th edition. Churchill Livingstone Elsevier. 2011

Serpell JW, Yeung MJ, Grodski S. The motor fibers of the recurrent laryngeal nerve are located in the anterior extralaryngeal branch. Ann Surg. 2009. 249:648-52

Barczyński M, Stopa M, Konturek A, Nowak W. The overwhelming majority but not all motor fibers of the bifid recurrent laryngeal nerve are located in the anterior extralaryngeal branch. World J Surg. 2016; 40(3):629-35. doi: 10.1007/s00268-015-3257-4

Gurleyik E. Location of motor fibers within branches of the recurrent laryngeal nerve with extralaryngeal terminal bifurcation; Functional identification by intraoperative neuromonitoring. Surgery 2015; 158(5):1339-44

Campos BA, Henriques PRF. Relationship between the recurrent laryngeal nerve and the inferior thyroid artery: a study in corpses. Rev. Hosp. Clín. Fac. Med. Sao Paulo. 2000; 55(6):195-200

Thomusch O, Sekulla C, Timmermann W, Neumann HJ, Kruse E, Muhlig HP, et al. Intraoperative neuromonitoring in thyroid surgery – Results of the German prospective multicentre study. Eur. Surg. 2003; 35(5):240-5.